SA-80 Series

Optex FA

  • Rango de medición de 0 a 400ºC 
  • Respuesta rápida: 100 ms
  • Grado IP67
  • Salida 4-20 mA
  • Gran area de sensado, distancia 500 mm
Especificaciones

Model SA-80T
2A 4A
Measurement
range
0 to 200°C (32 to 392°F) 0 to 400°C (32 to 752°F)
Field of view ø80/500 mm
Optics Silicone lens
Sensing element/
spectral response
Thermopile?8?14μm
Response time 100 ms/90% response
Accuracy*1 0 to 200°C (32 to 392°F): ±2°C (3.6°F),
201 to 400°C (393.8 to 752°F): ±1%
Repeatability ±1°C (1.8°F) of reading
Analog output 4 to 20 mA
Emissivity 0.95 (fixed)
Supply voltage/
current consumption
12 to 24 VDC ±10%/70 mA or less
Ambient temperature 0 to 70°C (32 to 158°F)
Ambient humidity 35 to 85% RH (no condensation)
Storage temperature −20 to 70°C (−4 to 158°F)
Vibration
resistance
10 to 55 Hz; amplitude 1.5 mm; 
2 hours in each of the X, Y, and Z directions
Water resistance IP67
Material SUS/AI
Weight Approx. 180 g
Standard included
accessories
Mounting nut ×2

DESCARGAS
CONTACTANOS